Bubble Leak Integrity Package Testing | Keystone Compliance (2024)

What is Bubble Leak Package Testing?

Bubble leak testing detects gross leaks in packaging. Detecting gross leaks in packaging by internal pressurization is also called the bubble test. This packaging test type is primarily used for tray/pouch packaging. It can detect leaks as small as 250 microns. Bubble leak integrity testing is destructive. Therefore, it requires entry into the package to supply internal air pressure.

As a leader in package compliance testing, Keystone understands the importance of bubble leak integrity testing. Our knowledge of the distribution system and packaging compliance standards has allowed us to create a streamlined approach to package validation. From test plan to test report, Keystone Compliance walks customers through the entire process.

Contact us to receive more information on bubble leak package integrity testing.If you are ready to start your bubble leak package compliance testing, request a quote.

Why is Bubble Leak Compliance Testing Important?

Internal pressurization and bubble testing provide a practical way to examine packages for gross leaks. As mentioned above, bubble leak testing indicates the breach of a sterile barrier.

Sterile barriers are used when designing packaging for medical devices. From manufacturer to end-user, hospital, doctor’s office, etc., a medical device will undergo stress throughout the distribution process. The loss of sterility in a package can result in returns, expensive replacement costs, and loss of customer trust.

Bubble Leak Integrity Test Process

Before testing, several specimens are chosen to permit an adequate determination of representative performance. In most cases, conditioning is to be at equilibrium with normal room temperature.

First, the package is inflated underwater. The inflation is to a predetermined pressure. Next, the package is observed for leaks. Failure is indicated by a steady stream of air bubbles.

The differential pressure can be increased or decreased. It is important to have repeatable results. Therefore, establishing a test pressure for each package is important. The method of pressurization, size and material will also play a factor in attaining repeatable results.

Higher pressure increases sensitivity. Likewise, lower pressure reduces sensitivity. The use of a bleed-off control valve with a pressure monitoring device will aid in stabilizing the test pressure. This assists in reducing excessive pressurization.

To complete bubble leak testing, three primary pieces of equipment are used.

  1. A pressure delivery system. This system includes a pressure monitoring gauge and bleed-off control valve. The system must be capable of delivering air at a pressure of 0-50 mbar.
  2. A needle. This package puncturing device allows the insertion of air from the pressure delivery system.
  3. A water container. The device being tested must be covered with at least one inch of water.

Upon completion of testing, a report is issued, providing the following information.

  • The date, operator’s name, and package type
  • Any identification numbers such as serial numbers
  • The defect size used to establish the test sensitivity
  • The test pressure and use of blocking agents, if any
  • The total number of test packages
  • The number of packages that passed
  • The number of packages exhibiting leaks and the location of each leak

Keystone’s Bubble Leak Testing Equipment and Capabilities

Keystone Compliance utilizes numerous pressure delivery systems, vacuum chambers, and open/closed package test fixtures to provide expert package integrity testing. Our dozens of thermal chambers range from reach-in to large walk-in chambers up to 1,300 cu. ft.

Additionally, we own shakers up to 12 kips, and multiple compression/tensile testers. Keystone offers complete pack-out services and testing for all types of flexible and rigid packages.

ASTM F2096 Bubble Leak Testing

Bubble leak testing to ASTM F2096 can be applied to many different packages. Large and long packages that do not fit other package integrity test methods can be tested to this standard. Bubble leak testing is also used for packages with unique sizes and shapes.

ASTM F2096 is ideal for medical packaging. However, this test standard has not been evaluated for use with porous materials other than spun-bonded polyolefin or with nonporous packaging.

ASTM D3078 Bubble Emission Testing

ASTM D3078 detects gross leaks in flexible packaging containing a headspace gas.

The test specimen is first submerged in a fluid contained in the vessel within the vacuum chamber. Next, a vacuum level is chosen to optimize the sensitivity of the test. The vacuum is then released. The unit is examined for the presence of test fluid in the specimen. If there are no bubbles observed and no test fluid is found in the specimen, the test unit has passed the test.

Expert Bubble Leak Package Integrity Testing

Keystone Compliance partners with customers to achieve package compliance. Our accurate test reports are delivered quickly. Our proven process helps avoid product launch delays. In addition to bubble leak and bubble emission testing, Keystone has a full scope of expertise including compression, drop, and accelerated aging.

As experts in medical package testing, we know the appropriate test pressure to use. We also understand and can explain which packages meet the requirements and which ones do not. Our lab is ISTA 17025 and ASTM certified.

Ready to get started? We are. Request a quote to experience the Keystone Compliance difference. Contact us to learn why we are one of the fastest-growing package test labs in the country.

Bubble Leak Integrity Package Testing | Keystone Compliance (2024)

FAQs

What is the standard for bubble leak testing? ›

An ASTM F2096 test submerges a packet or pouch under at least one inch of water. A low pressure is supplied to the packaging in a controlled flow and the packaging is closely monitored for any signs of escaping air. A continuous flow of bubbles indicates a leak and shows that any sterile barriers have been breached.

What is the ASTM standard for leak test? ›

Summary of ASTM D4991 Leak Testing Information

The ASTM vacuum method is suitable for testing rigid containers intended for the transportation of hazardous liquids. This standard does not purport to address all of the safety concerns associated with its use.

What is the ASTM D3078 test? ›

The ASTM-D3078 is the standard test method for determining gross leaks in flexible packaging containing a headspace gas and uses a bubble emission test to identify the leak. The test is conducted by submerging a test specimen in immersion fluid within the confines of a vacuum chamber.

What is a bubble test for air leaks? ›

Bubble Test/Submersion Test

Perhaps the most basic air leak testing method, bubble testing involves pressurizing the part or vessel, submerging it in water, and watching for bubbles caused by escaping air/gas. The size of the leak is directly proportional to the intensity and size of the bubbles created.

What is the ASME standard for leak testing? ›

Examinations for leaks (Paragraph 345.2. 2 (a) – ASME B31. 3): A leak test shall be maintained for at least 10 min, and all joints and connections shall be examined for leaks.

What is the ISO standard for leak test? ›

ISO 20486:2017 specifies the calibration of those leaks that are used for the adjustment of leak detectors for the determination of leakage rate in everyday use. One type of calibration method is a comparison with a reference leak. In this way, the leaks used for routine use become traceable to a primary standard.

What is ASTM B117 11 standard? ›

The ASTM B117 provides a controlled corrosive atmosphere for specimens of coated metals exposed in a test chamber. The salt spray chamber adheres to ASTM B117 standard.

What is ASTM e2930 13 2021? ›

1.1 This practice describes a method for determining the leakage rate of a vessel subject to a positive pressure difference. The technique is based upon evaluation of the change of mass within the test object based on a pressure decay measurement.

What is the limit for a leak test? ›

The leak test pressure limit for leak tests typically uses low pressure. Most codes for leak test pressure limits call for the pressure to be at least 15 psi or 25% of the design pressure (whichever pressure is less).

What is the ASTM D638 test standard? ›

ASTM D638 is the most common testing standard for determining the tensile properties of reinforced and non-reinforced plastics.

What is the ASTM test method f2547 18? ›

ASTM F 2547‐18 Standard test method for determining the attenuation properties in a primary x‐ray beam of materials used to protect against radiation generated during the use of x‐ray equipment.

What is the ASTM D877 test method? ›

ASTM D877 - Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes. 1.1 This test method describes two procedures, A and B, for determining the electrical breakdown voltage of insulating liquid specimens. The breakdown test uses ac voltage in the power-frequency range from 45 to 65 Hz.

What pressure is needed for bubble leak test? ›

Test Equipment Required for Bubble Leak Testing

The system must be capable of delivering air at a pressure of 0-50 mbar. The second piece of equipment is the needle. This package puncturing device allows the insertion of air from the pressure delivery system.

How do you do a bubble test? ›

You'll be asked to lie down on your left side with your left arm above your head. As the bubbles from the injection flows through your bloodstream and into your heart, your physiologist will track them using an echocardiogram. If your heart is normal, the bubbles will only be visible in the right side.

What is the bubble testing method? ›

Direct-Pressure Technique

Bubble testing is often associated with package leak detection, but there are other forms of bubble leak testing as well. The direct-pressure technique is one such method that involves pressurizing a component with gas and submerging it in a solution or applying a solution to the outside.

What is the ASTM standard for air leakage? ›

ASTM E 1186 is a testing standard for air leakage as applies to building envelopes & air barrier systems. Air leakage is the cause for many concerns related to occupant comfort and indoor air quality. It also affects the energy used when heating, cooling, or dehumidifying a building.

What is an acceptable leak down test? ›

For normally aspirated engines, 5 to 10 percent loss indicates the engine in great condition. If an engine reads between 15-20 percent, it's not a reason for condemning the engine – but be more concerned about where the leakage is occurring. And at 30 percent, there are some major problems and an overhaul is likely.

What is the ASTM standard for foam testing? ›

ASTM D3574 is the key standard for measuring and evaluating flexible foam properties, including: Density. IFD (Indentation force deflection) CFD (Compression force deflection)

What is the standard for air leakage test? ›

0.40 CFM/ft2 = Standard Practice

2021 International Energy Conservation Code (IECC) requires building thermal envelope testing in accordance with ASTM E779, ANSI/RESNET/ICC 380, ASTM E3158, or ASTM E1827 such that the measured air leakage shall not exceed 0.40 CFM75/ft2.

Top Articles
Latest Posts
Article information

Author: Neely Ledner

Last Updated:

Views: 5857

Rating: 4.1 / 5 (62 voted)

Reviews: 93% of readers found this page helpful

Author information

Name: Neely Ledner

Birthday: 1998-06-09

Address: 443 Barrows Terrace, New Jodyberg, CO 57462-5329

Phone: +2433516856029

Job: Central Legal Facilitator

Hobby: Backpacking, Jogging, Magic, Driving, Macrame, Embroidery, Foraging

Introduction: My name is Neely Ledner, I am a bright, determined, beautiful, adventurous, adventurous, spotless, calm person who loves writing and wants to share my knowledge and understanding with you.